A high-intensity positron beam is used for specific in situ monitoring of thermally activated fast defect annealing in Cu and Ni on a time scale of minutes. The atomistic technique of positron-electron annihilation is combined with macroscopic high-precision length-change measurements under the same thermal conditions. The combination of these two methods as demonstrated in this case study allows for a detailed analysis of multistage defect annealing in solids distinguishing vacancies, dislocations, and grain growth.