In Situ Probing of Fast Defect Annealing in Cu and Ni with a High-Intensity Positron Beam

Author(s)
Bernd Oberdorfer, Eva-Maria Steyskal, Wolfgang Sprengel, Werner Puff, Philip Pikart, Christoph Hugenschmidt, Michael Zehetbauer, Reinhard Pippan, Roland Würschum
Abstract

A high-intensity positron beam is used for specific in situ monitoring of thermally activated fast defect annealing in Cu and Ni on a time scale of minutes. The atomistic technique of positron-electron annihilation is combined with macroscopic high-precision length-change measurements under the same thermal conditions. The combination of these two methods as demonstrated in this case study allows for a detailed analysis of multistage defect annealing in solids distinguishing vacancies, dislocations, and grain growth.

Organisation(s)
Physics of Nanostructured Materials
External organisation(s)
Technische Universität Graz, Technische Universität München, Österreichische Akademie der Wissenschaften (ÖAW)
Journal
Physical Review Letters
Volume
105
No. of pages
4
ISSN
0031-9007
DOI
https://doi.org/10.1103/PhysRevLett.105.146101
Publication date
2010
Peer reviewed
Yes
Austrian Fields of Science 2012
103018 Materials physics
Portal url
https://ucris.univie.ac.at/portal/en/publications/in-situ-probing-of-fast-defect-annealing-in-cu-and-ni-with-a-highintensity-positron-beam(91603e7c-18cb-45cf-bd2c-ac0a6105fa95).html